Combison
Combison™ Uno A
System range
Size, mm
600x600 1200x600
T24
Thickness 35 35
M188 M188
System and product description
For use as a sound absorbing ceiling and for sound insulation between rooms if the partitions do not extend all the way up to the soffit. Also suitable for sound reduction of vertical noise, generated by ventilation, foot steps etc. Ecophon Combison Uno A has an exposed grid system. Each tile is demountable.

The system consists of Ecophon Combison Uno A tiles and Ecophon Connect grid systems, with an approximate weight of 13 kg/m². The tiles are manufactured from high density glass wool, with a bonded gypsum board (13 mm) on the back of the tile. The visible surface has an Akutex™ FT coating and the edges are primed.

For best performance and system quality, use Ecophon Connect grid and accessories. The grid is manufactured from galvanized steel.
Acoustics
Acoustic:
Sound Absorption: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation: Dn,c,w=40 dB according to ISO 140-9 and evaluation according to EN ISO 717. CAC=44 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
Sound Privacy: Not applicable
Product Combison Uno A
o.d.s mm 200
absorption class C
NRC
SAA
Technical properties
Accessibility: The tiles are easily demountable. Minimum demounting depth according to installation diagrams.
Cleanability: Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance: White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd*m-2lx-1. Gloss < 1.
Environmental influence: Fully recyclable
Indoor Climate: Recommended by the Swedish Asthma and Allergy Association.
Influence of climate: The tiles withstand a permanent ambient RH up to 75% at 30°C without sagging, warping or delaminating (ISO 4611).
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Technical properties, Fire safety.
Country Standard Class
Europe EN 13501-1 A2-s1,d0
Mechanical properties: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Max live load (N) Min load bearing capacity (N)
M188, 600x600 0 220
Installation: Installed according to system range which includes information regarding minimum overall depth of system.
We help you with technical solutions and answers to your questions about our products.
A new feature turns watching installation diagrams into a 3D experience! Add another dimension to watching our installation diagrams. With our latest innovation we let you twist and turn and view close-ups directly on your computer.
The new Acoustics features applied room acoustics for Office, Education and Healthcare premises. Here you can explore the individual segments, and by using the room selector you can read up on the specific needs and acoustic solutions for that particular room.
Tell a friend Close

Your friends name:
*
Your name:
*