Search
Products
Solutions
References
Acoustics
Functional demands
Contact
About Ecophon
Career
SITEMAP
Focus
Focus additional systems
Master
Combison
Gedina
Advantage
Access
Sombra
Hygiene
Super G
Wall Panel
Ecophon Lighting
Focus™ A
Focus™ B
Focus™ C
Focus™ Dg
Focus™ Ds
Focus™ E
Focus™ Ebx
Focus™ F
Focus™ Wing
Focus Edge™ 500
Ecophon Focus™ Flexiform
Focus™ S-Line
Focus™ L-Line
Ecophon Focus™ Quadro E
Focus™ Frieze
Master™ A
Master™ B
Master™ C
Master™ Ds
Master™ E
Master™ F
Master™ Solo S
Master™ Baffle
Combison™ Uno A
Combison™ Uno Ds
Combison™ Duo A
Combison™ Duo E
Combison™ Barrier
Gedina™ A
Gedina™ E
Advantage™ A
Advantage™ E
Access™ A
Access™ C
Access™ E
Access™ Frieze
Sombra™ A
Sombra™ Ds
Hygiene Advance™ A C4
Hygiene Advance™ A C3
Hygiene Advance™ Baffle C3
Hygiene Advance™ Protection C3
Hygiene Advance™ Wall C3
Hygiene Foodtec™ A C3
Hygiene Foodtec™ Baffle C3
Hygiene Foodtec™ Wall C3
Hygiene Protec™ A C3
Hygiene Protec™ A C1
Hygiene Labotec™ Ds C1
Hygiene Performance™ A C4
Hygiene Performance™ A C3
Hygiene Performance™ A C1
Hygiene Meditec™ A C1
Hygiene Meditec™ E C1
Hygiene Lavanda™ T5 C3
Hygiene Foodtec™ Protection C3
Super G™
Super G™ Plus
Super G™ Dp XL
Wall Panel™ A
Wall Panel™ C
Ecophon Illuminated Level Change
Light Coffer
Dot™
Square 43™
Line™
WingLight™
Room types
Ideas and solutions
Colours and surfaces
Integrated lighting
Download our brochures here!
Concrete Core Activation
Connect Grids
Local references Germany
Local references Italy
Local references Sweden
Local references Netherlands
Local references
For Architects
For Acousticians
For Clients
For Users
Sound in offices
Noise in Offices
Ecophon Acoustic Bulletin
Accessibility
Cleanability
Visual appearance
Environment
Our certifications
Influence of climate
Fire Safety
Mechanical properties
CE-marking
Ecophon partners
Request information
Contact
ECO magazine- subscription
Subscribe to EcoMagazine
Disclaimer
Cookies
Trademarks
Testimonials
Available jobs
Workplace facts
Development opportunities
Environment Health Safety
HR Contact
Focus additional systems
Focus™ Frieze
Tell a friend
Print
E-tools
Cad Support
Specifications
Maintenance manual
System and product description
Installation
Acoustics
Technical info
System range
Size, mm
XL
2400x600
T24
•
Thickness
20
M110
System and product description
For applications where a smooth continuous transition between the ceiling and the wall is needed. The frieze can be connected to the wall without any visible trims. The tiles are not demountable.
The system consists of Ecophon Focus frieze tiles and Ecophon Connect grid systems, with an approximate weight of 3 kg/m². The tiles are manufactured from high density glass wool. The visible surface has an Akutex FT coating and the back of the tile is covered with glass tissue. The edges are painted.
For best performance and system quality, use Ecophon Connect grid and accessories. The grid is manufactured from galvanized steel.
M110
M110
Download installation guide
IG110
-Focus frieze
(1.68 MB)
Quantity specification (excl. wastage)
Installation diagram (M110) for Focus frieze
Size, mm
2400x600
1 Ecophon Focus Frieze
as required
2 Connect T24 Main runner
as required
3 Connect T24 Cross tee, L=600 mm
as required
4 Connect Adjustable hanger, installed at 1200 mm centres
as required
5 Connect Hanger clip
as required
6 Connect Direct bracket (only in combination with Frieze trim)
as required
7 Focus A or E, Master A or E
as required
8 Connect Frieze trim, fixed at 300 mm centres. If this solution is used on two opposite walls, the inner part if the ceiling needs to be stabilized towards the walls. Minimum free depth above tile 0 mm.
as required
9 Connect Frieze bracket, installed at 500 mm centre. Minimum free depth above tile 150 mm.
/cut tile with one bearing edge
10 Connect Wall bracket, L=600 mm, for distance profiles
as required
11 Acrylic sealant, (not supplied by Ecophon)
as required
Min. overall depth of system: with Adjustable hanger: 110 mm, with Direct bracket: 60 mm
-
Min. demounting depth: The system is non-demountable
-
Focus Frieze: Min. overall depth of system: 160 mm
-
Focus Frieze: Min. demounting depth: The system is non-demountable
-
Ecophon Focus frieze: can be divided in two parts if width is less than 300 mm
-
Acoustics
Acoustic:
product
Focus Frieze
o.d.s mm
200
absorption class
A
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation:
Dn,c,w=24 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=25 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
Sound Privacy:
AC(1.5)=190 according to ASTM E 1111 and E 1110.
αp Practical sound absorption coefficient
Frequency Hz
Technical info
Accessibility:
The tiles are not demountable.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping.
Light efficiency:
White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd*m-2lx-1. Gloss < 1.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Influence of climate:
Systemet klarar korrosivitetsklass C2 (miljöer med låg korrosionsrisk). Absorbenterna klarar dock 95% RF vid 30°C utan att formförändras (ISO 4611).
Indoor Climate:
Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
Environmental influence:
Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Technical properties, Fire safety.
Country
Class
Standard
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Installation:
Installed according to system range.
For Acousticians
"Acoustical evaluation of rooms requires several room acoustic descriptors. Reverberation time alone is not enough!" Erling Nilsson / Acoustics Specialist Ecophon