Search
Products
Solutions
References
Acoustics
Functional demands
Contact
About Ecophon
Career
SITEMAP
Focus
Focus additional systems
Master
Combison
Gedina
Advantage
Access
Sombra
Hygiene
Super G
Wall Panel
Ecophon Lighting
Focus™ A
Focus™ B
Focus™ C
Focus™ Dg
Focus™ Ds
Focus™ E
Focus™ Ebx
Focus™ F
Focus™ Wing
Focus Edge™ 500
Ecophon Focus™ Flexiform
Focus™ S-Line
Focus™ L-Line
Ecophon Focus™ Quadro E
Focus™ Frieze
Master™ A
Master™ B
Master™ C
Master™ Ds
Master™ E
Master™ F
Master™ Solo S
Master™ Baffle
Combison™ Uno A
Combison™ Uno Ds
Combison™ Duo A
Combison™ Duo E
Combison™ Barrier
Gedina™ A
Gedina™ E
Advantage™ A
Advantage™ E
Access™ A
Access™ C
Access™ E
Access™ Frieze
Sombra™ A
Sombra™ Ds
Hygiene Advance™ A C4
Hygiene Advance™ A C3
Hygiene Advance™ Baffle C3
Hygiene Advance™ Protection C3
Hygiene Advance™ Wall C3
Hygiene Foodtec™ A C3
Hygiene Foodtec™ Baffle C3
Hygiene Foodtec™ Wall C3
Hygiene Protec™ A C3
Hygiene Protec™ A C1
Hygiene Labotec™ Ds C1
Hygiene Performance™ A C4
Hygiene Performance™ A C3
Hygiene Performance™ A C1
Hygiene Meditec™ A C1
Hygiene Meditec™ E C1
Hygiene Lavanda™ T5 C3
Hygiene Foodtec™ Protection C3
Super G™
Super G™ Plus
Super G™ Dp XL
Wall Panel™ A
Wall Panel™ C
Ecophon Illuminated Level Change
Light Coffer
Dot™
Square 43™
Line™
WingLight™
Room types
Ideas and solutions
Colours and surfaces
Integrated lighting
Download our brochures here!
Concrete Core Activation
Connect Grids
Local references Germany
Local references Italy
Local references Sweden
Local references Netherlands
Local references
For Architects
For Acousticians
For Clients
For Users
Sound in offices
Noise in Offices
Ecophon Acoustic Bulletin
Accessibility
Limpieza
Visual appearance
Environment
Our certifications
Influence of climate
Fire Safety
Mechanical properties
CE-marking
Ecophon partners
Request information
Contact
ECO magazine- subscription
Subscribe to EcoMagazine
Disclaimer
Cookies
Trademarks
Testimonials
Available jobs
Workplace facts
Development opportunities
Environment Health Safety
HR Contact
Focus additional systems
Focus™ L-Line
Tell a friend
Print
E-tools
Cad Support
Specifications
Maintenance manual
System and product description
Installation
Acoustics
Technical info
System range
Size, mm
1200x162
1200x600
T24
•
•
Thickness
20
20
M29ic
M29ec
M29
M30
M30ic
M30ec
System and product description
Ecophon Focus L-line is used to create smooth transitions between wall and ceiling, or for transitions between different levels of the ceiling surface. The difference in level is 150 or 588 mm, depending on the method of installation. The Ecophon Focus L-line panels are not directly demountable. The systems consist of Ecophon Focus L-line panels and Ecophon Connect grid systems. The weight is approximately 4 kg/panel. The panels are manufactured from high density moulded glass wool. The visible surface has an Akutex FT coating. The edges are painted. Straight sides have edge detail E, curved sides have edge detail B. The radius is 100 mm. For best performance and system quality, use Ecophon Connect grid and accessories. The grid is manufactured from galvanized steel.
M29ic
M29ec
M29
M30
M30ic
M30ec
M29ic
Quantity specification (excl. wastage)
Internal corner (M29IC) for Focus L-line vertical installation
Size, mm
1200x162
1 Ecophon Focus L-Line
-
2 Connect T24 Cross Tee
-
3 Connect T24 Main runner
-
4 Connect Adjustable hanger, installed at 1200 mm centres
-
5 Connect Hanger clip
-
6 Connect Hook (3 pieces/corner in corner kit)
-
7 Connect T24 Main runner with Connect F-trim 10
-
8 Connect L-coupling (2 pieces/corner in corner kit)
-
9 Connect F-trim 10
-
Ecophon Focus L-Line V IC contains:
-
1 pcs L-Line V IC panel right, 1 pcs L-Line V IC panel left, 1 tube Design sealant, 3 pcs Connect Hook, 2 pcs Connect L-coupling, 2 pcs Connect Angle bracket.
-
M29ec
Quantity specification (excl. wastage)
External corner (M29EC) for Focus L-line vertical installation
Size, mm
1200x162
1 Focus L-Line
-
2 Connect T24 Cross Tee
-
3 Connect Adjustable hanger, installed at 1200 mm centres
-
4 Connect Hanger clip
-
5 Connect T24 Main runner
-
6 Connect Hook (3 pieces/corner in corner kit)
-
7 Connect T24 Main runner with Connect F-trim 10
-
8 Connect L-coupling (2 pieces/corner in corner kit)
-
9 Connect F-trim 10
-
Ecophon Focus L-Line V EC contains:
-
1 pcs L-Line V EC panel right, 1 pcs L-Line V EC panel left, 1 tube Design sealant, 3 pcs Connect Hook, 2 pcs Connect L-coupling, 2 pcs Connect Angle bracket.
-
M29
Quantity specification (excl. wastage)
Installation diagram (M29) for Focus L-Line, vertical installation
Size, mm
1200x600
1 Ecophon Focus L-Line
as required
2 Connect T24 Main runner
as required
3 Edge B without profile
as required
4 Connect Adjustable hanger, installed at 1200 mm centres
as required
5 Connect T24 Cross Tee
as required
6 Connect Hanger clip
as required
7 Connect T24 Main runner with Connect F-trim 10
as required
8 Dimension: c=162 mm centres, h=588 mm
as required
M30
Quantity specification (excl. wastage)
Installation diagram (M30) for Focus L-line, horizontal installation
Size, mm
1200x600
1 Focus L-line
as required
2 Connect T24 Cross Tee
as required
3 Connect Adjustable hanger, installed at 1200 mm centres
as required
4 Edge B without profile
as required
5 Connect T24 Main runner
as required
6 Connect Hanger clip
as required
7 Connect T24 Main runner with Connect F-trim 10
as required
8 Connect F-trim 10
as required
9 Dimension: c=600 mm centres, h=150 mm
-
M30ic
Quantity specification (excl. wastage)
Internal corner (M30IC) for Focus L-line horizontal Installation
Size, mm
1200x600
1 Ecophon Focus L-Line
as required
2 Connect T24 Cross Tee
as required
3 Connect Adjustable hanger, installed at 1200 mm centres
as required
4 Connect Hanger clip
as required
5 Connect T24 Main runner
as required
6 Connect Hook (3 pieces/corner in corner kit)
as required
7 Connect T24 Main runner with Connect F-trim 10
as required
8 Connect L-coupling (2 pieces/corner in corner kit)
as required
9 Connect F-trim 10
as required
Ecophon Focus L-Line H IC contains:
-
1 pcs L-Line H IC panel right, 1 pcs L-Line H IC panel left, 1 tube Design sealant, 3 pcs Connect Hook, 2 pcs Connect L-coupling, 2 pcs Connect Angle bracket.
-
M30ec
Quantity specification (excl. wastage)
External corner (M30EC) for Focus L-line, horizontal installation
Size, mm
1200x600
1 Ecophon Focus L-Line
as required
2 Connect T24 Main runner with Connect F-trim 10
as required
3 Connect Adjustable hanger, installed at 1200 mm centres
as required
4 Connect Hanger clip
as required
5 Connect T24 Cross Tee
as required
6 Connect T24 Main runner
as required
7 Connect Hook (3 pieces/corner in corner kit)
as required
8 Connect L-coupling (2 pieces/corner in corner kit)
as required
9 Connect F-trim 10
as required
Ecophon Focus L-Line H EC contains:
-
1 pcs L-Line H EC panel right, 1 pcs L-Line H EC panel left, 1 tube Design sealant, 3 pcs Connect Hook, 2 pcs Connect L-coupling, 2 pcs Connect Angle bracket.
-
Acoustics
Acoustic:
product
Focus L-line
o.d.s mm
200
absorption class
B
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654.
Sound Insulation:
Dn,c,w=24 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=25 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
Sound Privacy:
Not applicable
αp Practical sound absorption coefficient
Frequency Hz
— Ecophon Focus L-line 200 mm o.d.s.
o.d.s = overall depth of system
Technical info
Accessibility:
The tiles are demountable.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance:
White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd*m-2lx-1. Gloss < 1.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate:
Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
Environmental influence:
Fully recyclable
Fire safety:
See Technical properties, Fire safety.
Country
Class
Standard
Europe
EN 13501-1
B-s1,d0
Mechanical properties:
Additional live load has to be secured to the soffit.
Installation:
Installed according to system range. Focus L-line 90° internal and external corners are supplied in sets with all necessary installation accessories. (Please note: different for horizontal and vertical installation).
For Acousticians
"Acoustical evaluation of rooms requires several room acoustic descriptors. Reverberation time alone is not enough!" Erling Nilsson / Acoustics Specialist Ecophon