Search
Products
Solutions
References
Acoustics
Functional demands
Contact
About Ecophon
Career
SITEMAP
Focus
Focus additional systems
Master
Combison
Gedina
Advantage
Access
Sombra
Hygiene
Super G
Wall Panel
Ecophon Lighting
Focus™ A
Focus™ B
Focus™ C
Focus™ Dg
Focus™ Ds
Focus™ E
Focus™ Ebx
Focus™ F
Focus™ Wing
Focus Edge™ 500
Ecophon Focus™ Flexiform
Focus™ S-Line
Focus™ L-Line
Ecophon Focus™ Quadro E
Focus™ Frieze
Master™ A
Master™ B
Master™ C
Master™ Ds
Master™ E
Master™ F
Master™ Solo S
Master™ Baffle
Combison™ Uno A
Combison™ Uno Ds
Combison™ Duo A
Combison™ Duo E
Combison™ Barrier
Gedina™ A
Gedina™ E
Advantage™ A
Advantage™ E
Access™ A
Access™ C
Access™ E
Access™ Frieze
Sombra™ A
Sombra™ Ds
Hygiene Advance™ A C4
Hygiene Advance™ A C3
Hygiene Advance™ Baffle C3
Hygiene Advance™ Protection C3
Hygiene Advance™ Wall C3
Hygiene Foodtec™ A C3
Hygiene Foodtec™ Baffle C3
Hygiene Foodtec™ Wall C3
Hygiene Protec™ A C3
Hygiene Protec™ A C1
Hygiene Labotec™ Ds C1
Hygiene Performance™ A C4
Hygiene Performance™ A C3
Hygiene Performance™ A C1
Hygiene Meditec™ A C1
Hygiene Meditec™ E C1
Hygiene Lavanda™ T5 C3
Hygiene Foodtec™ Protection C3
Super G™
Super G™ Plus
Super G™ Dp XL
Wall Panel™ A
Wall Panel™ C
Ecophon Illuminated Level Change
Light Coffer
Dot™
Square 43™
Line™
WingLight™
Room types
Ideas and solutions
Colours and surfaces
Integrated lighting
Download our brochures here!
Concrete Core Activation
Connect Grids
Local references Germany
Local references Italy
Local references Sweden
Local references Netherlands
Local references
For Architects
For Acousticians
For Clients
For Users
Sound in offices
Noise in Offices
Ecophon Acoustic Bulletin
Accessibility
Cleanability
Visual appearance
Environment
Our certifications
Influence of climate
Fire Safety
Mechanical properties
CE-marking
Ecophon partners
Request information
Contact
ECO magazine- subscription
Subscribe to EcoMagazine
Disclaimer
Cookies
Trademarks
Testimonials
Available jobs
Workplace facts
Development opportunities
Environment Health Safety
HR Contact
Gedina
Gedina™ E
Tell a friend
Print
E-tools
Cad Support
Specifications
Maintenance manual
System and product description
Installation
Acoustics
Technical info
System range
Size, mm
600x600
1200x600
1200x1200
T15
•
•
•
T24
•
•
•
Thickness
15
15
15
M121
M270
M121
M121
System and product description
For applications requiring a standard ceiling which is easy to install and demount, but where strict functional requirements are needed. Ecophon Gedina E has a recessed visible grid and a tegular edge design, creating a ceiling with a shadow effect that accentuates each tile and partially conceals the grid system. The visible surface of each tile is 7 mm below the grid. Each tile is easily demountable. Note that installation according to installation diagram M121 contributes to a higher live load capacity compared to M270.
The system consists of Ecophon Gedina E tiles and Ecophon Connect grid systems, with an approximate weight of 2,5 kg/m². The tiles are manufactured from high density glass wool. The visible surface has an Akutex T coating and the back of the tile is covered with glass tissue. The edges are painted. The grid is manufactured from galvanized steel. For best performance and system quality, use Ecophon Connect grid and accessories.
M121
M270
M121
Quantity specification (excl. wastage)
Installation diagram (M121) for Gedina E
Size, mm
600x600
1200x600
1200x1200
1 Ecophon Gedina E
2,8/m²
1,4/m²
0,7/m²
2 Connect T24 or T15 Main runner, installed at 1200 mm centres
0,9m/m²
0,9m/m²
0,9m/m²
3 Connect T24 or T15 Cross tee, L=1200 mm, installed at 600 mm centres
1,7m/m²
1,7m/m²
0,9m/m²
4 Connect T24 or T15 Cross tee, L=600 mm
0,9m/m²
-
-
5 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm)
0,7/m²
0,7/m²
0,7/m²
6 Connect Hanger clip
0,7/m²
0,7/m²
0,7/m²
7 For direct installation: Connect Direct bracket, installed at 1200 mm centres
0,7/m²
0,7/m²
0,7/m²
8 Connect Angle trim, fixed at 300 mm centres
as required
as required
as required
9 Connect Shadow-line trim, fixed at 300 mm centres
as required
as required
as required
10 Connect E-plug (for Shadow-line trim)
as required
as required
as required
Min. overall depth of system, with Adjustable hanger: 110 mm, with Direct bracket: 60 mm
-
-
-
Min. demounting depth: T15: 110 mm (1200x1200:160 mm). T24: 90 mm. (1200x1200:120 mm)
-
-
-
M270
Quantity specification (excl. wastage)
Size, mm
600x600
1 Ecophon Gedina E
2,8/m²
2 null
0,56m/m²
3 null
1,7m/m²
4 Connect T24 Cross tee, L=600 mm centres
1,1m/m²
5 null
0,46/m²
6 null
0,46/m²
7 Connect Angle trim, fixed at 300 mm centres
as required
8 Alt. Connect Shadow-line trim, fixed c300
as required
Min. overall depth of system, with Adjustable hanger: 100 mm, with Direct bracket: 50 mm
-
Min. demounting depth: 120 mm
-
Acoustics
Acoustic:
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation:
Dn,c,w=20 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=21 dB according to ASTM E 1414 and evaluation according to ASTM E 413
Sound Privacy:
AC(1.5)=180 according to ASTM E 1111 and E 1110.
αp Practical sound absorption coefficient
Frequency Hz
— Ecophon Gedina E 200 mm o.d.s.
--- Ecophon Gedina E 60 mm o.d.s.
o.d.s = overall depth of system
product
Gedina E
o.d.s mm
60
80
110
200
absorption class
C
B
A
A
Technical info
Accessibility:
The tiles are easily demountable. Minimum demounting depth according to installation diagrams.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping.
Light efficiency:
White 010, nearest NCS colour sample S 0502-Y, 84% light reflectance (of which more than 99% is diffuse reflection)
Environmental influence:
Granted the Nordic Swan eco-label. Fully recyclable.
Indoor Climate:
Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Technical properties, Fire safety.
Country
Class
Standard
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Inst. Diagr., Size (mm)
Max live load (N)
Min load bearing capacity (N)
M270
, 600x600
20
160
Installation:
Installed according to system range.
For Acousticians
"Acoustical evaluation of rooms requires several room acoustic descriptors. Reverberation time alone is not enough!" Erling Nilsson / Acoustics Specialist Ecophon
Copyright © 2002-2010 Ecophon Group. All rights reserved.
Trademarks
Cookies
Disclaimer
Tell a friend
Close
Your friends name:
*
Your friends email:
*
Your name:
*
Your e-mail:
*
Your message: