Hygiene
Hygiene Advance™ Baffle C3
System range
Size, mm
1200x600
T24
Thickness 40
M259 M260
System and product description
Ecophon Hygiene Advance Baffle C3 is an open system with vertical baffles intended for use in environment where there is a high level of contamination, and where frequent cleaning is required. This system is used mainly in premises where it is not possible to install a wall to wall ceiling because of sprinkler systems, installations or skylights, etc. Examples of applications: areas with high levels of airborne grease, areas exposed to spatter from meat juices, fruit juices or other liquids.

The system consists of Ecophon Hygiene Advance Baffles, which have a core of high density glass wool encapsulated in a smooth high-performance film that is impervious to particles and water. The film is also dirt-repellent and resistant to most chemicals. The supporting structure is a corrosion protected exposed Connect T24 C3 grid of lacquered galvanised steel. The weight of the system is 3-4 kg/m².
Acoustics
Acoustic:
product Hygiene Advance Baffle C3 in rows, c 600 mm, with ~1,4 baffles per m² of ceiling area Hygiene Advance Baffle C3 in chequered pattern, with ~1,3 baffles per m² of ceiling area
o.d.s mm - -
absorption class D C
Sound Absorption: Test results according to EN ISO 354.
Classification according to EN ISO 11654.
Sound Insulation: Not applicable.
Sound Privacy: Not applicable
Technical info
Accessibility: The tiles are demountable.
Cleanability: Daily dusting, vacuum cleaning, manual wet cleaning and high-pressure washing. Water temperature max. 70°C. Can withstand the use of common disinfecting chemicals.
Light efficiency: White 141, nearest NCS colour sample S 1000-N, 73% light reflectance. Please note: There is a small difference in gloss between the Hygiene Advance tile and the Hygiene Advance perimeter tile.
Influence of climate: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate: Can be used in rooms classified as ISO class 5/M2.5.
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. See Technical properties, Fire safety.
Country Class Standard
Europe EN 13501-1 A2-s1,d0
Mechanical properties: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Installation: Installed according to system range. Cut tiles must be sealed with Connect Hygiene Advance Tape.
"Acoustical evaluation of rooms requires several room acoustic descriptors. Reverberation time alone is not enough!" Erling Nilsson / Acoustics Specialist Ecophon