Hygiene
Hygiene Advance™ Wall C3
System range
Size, mm
1200x600
Thickness 40
M258
System and product description
Ecophon Hygiene Advance Wall C3 is a sound-absorbing wall panel system intended for use in environment where there is a high level of contamination, and where frequent cleaning is required. It is intended for use on walls above the occupied area or where there is no risk for mechanical impact. Examples of applications: areas with high levels of airborne grease, areas exposed to splatter from meat juices, fruit juices or other liquids.

The system consists of Ecophon Hygiene Advance Wall panel, which has a core of high density glass wool encapsulated in a smooth high-performance film that is impervious to particles and water. The film is also dirt-repellent and resistant to most chemicals. The fixing details Connect Wall fixing C3 are made of stainless steel wire. The panel is positioned with an airgap of 40 mm to the surface behind allowing for air to circulate and for cleaning. The weight of the system is approximately 3 kg/pcs.
Acoustics
Acoustic:
Sound Absorption: Test results according to EN ISO 354.
Classification according to EN ISO 11654.
Sound Insulation: Not applicable.
Sound Privacy: Not applicable
product Hygiene Advance Wall C3
o.d.s mm 80 (refers to the surface of the panel)
absorption class B
Technical info
Accessibility: The tiles are demountable.
Cleanability: Daily dusting, vacuum cleaning, manual wet cleaning and high-pressure washing. Water temperature max. 70°C. Can withstand the use of common disinfecting chemicals.
Light efficiency: White 141, nearest NCS colour sample S 1000-N, 73% light reflectance. Please note: There is a small difference in gloss between the Hygiene Advance tile and the Hygiene Advance perimeter tile.
Influence of climate: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate: Can be used in rooms classified as ISO class 5/M2.5.
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. See Technical properties, Fire safety.
Country Class Standard
Europe EN 13501-1 A2-s1,d0
Mechanical properties: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Installation: Installed according to system range. Cut tiles must be sealed with Connect Hygiene Advance Tape.
"Acoustical evaluation of rooms requires several room acoustic descriptors. Reverberation time alone is not enough!" Erling Nilsson / Acoustics Specialist Ecophon