Search
Products
Solutions
References
Acoustics
Functional demands
Contact
About Ecophon
Career
SITEMAP
Focus
Focus additional systems
Master
Combison
Gedina
Advantage
Access
Sombra
Hygiene
Super G
Wall Panel
Ecophon Lighting
Focus™ A
Focus™ B
Focus™ C
Focus™ Dg
Focus™ Ds
Focus™ E
Focus™ Ebx
Focus™ F
Focus™ Wing
Focus Edge™ 500
Ecophon Focus™ Flexiform
Focus™ S-Line
Focus™ L-Line
Ecophon Focus™ Quadro E
Focus™ Frieze
Master™ A
Master™ B
Master™ C
Master™ Ds
Master™ E
Master™ F
Master™ Solo S
Master™ Baffle
Combison™ Uno A
Combison™ Uno Ds
Combison™ Duo A
Combison™ Duo E
Combison™ Barrier
Gedina™ A
Gedina™ E
Advantage™ A
Advantage™ E
Access™ A
Access™ C
Access™ E
Access™ Frieze
Sombra™ A
Sombra™ Ds
Hygiene Advance™ A C4
Hygiene Advance™ A C3
Hygiene Advance™ Baffle C3
Hygiene Advance™ Protection C3
Hygiene Advance™ Wall C3
Hygiene Foodtec™ A C3
Hygiene Foodtec™ Baffle C3
Hygiene Foodtec™ Wall C3
Hygiene Protec™ A C3
Hygiene Protec™ A C1
Hygiene Labotec™ Ds C1
Hygiene Performance™ A C4
Hygiene Performance™ A C3
Hygiene Performance™ A C1
Hygiene Meditec™ A C1
Hygiene Meditec™ E C1
Hygiene Lavanda™ T5 C3
Hygiene Foodtec™ Protection C3
Super G™
Super G™ Plus
Super G™ Dp XL
Wall Panel™ A
Wall Panel™ C
Ecophon Illuminated Level Change
Light Coffer
Dot™
Square 43™
Line™
WingLight™
Room types
Ideas and solutions
Colours and surfaces
Integrated lighting
Download our brochures here!
Concrete Core Activation
Connect Grids
Local references Germany
Local references Italy
Local references Sweden
Local references Netherlands
Local references
For Architects
For Acousticians
For Clients
For Users
Sound in offices
Noise in Offices
Ecophon Acoustic Bulletin
Accessibility
Limpieza
Visual appearance
Environment
Our certifications
Influence of climate
Fire Safety
Mechanical properties
CE-marking
Ecophon partners
Request information
Contact
ECO magazine- subscription
Subscribe to EcoMagazine
Disclaimer
Cookies
Trademarks
Testimonials
Available jobs
Workplace facts
Development opportunities
Environment Health Safety
HR Contact
Hygiene
Hygiene Foodtec™ A C3
Tell a friend
Print
E-tools
Cad Support
Specifications
Maintenance manual
System and product description
Installation
Acoustics
Technical info
System range
Size, mm
600x600
600x600
1200x600
1200x600
Thickness
20
40
20
40
M249
M249
M249
M249
System and product description
Ecophon Hygiene Foodtec A C3 is a wall to wall, sound-absorbing ceiling system intended for environments where there is risk for contaminations, and where frequent cleaning is required. This system is recommended where humidity levels are occasionally high. Examples of applications: the food and beverage industries, restaurants and catering kitchens.
The system consists of Ecophon Hygiene Foodtec A tiles, which have a core of high density glass wool and a painted stain protected Akutex HS surface. The back and the edges are painted. The tile is designed to be demounted and cleaned on a regular basis. The supporting structure is a corrosion protected exposed Connect T24 C3 grid of lacquered galvanised steel. The weight of the system is 3-4 kg/m2. The tiles should be secured to the grid with Connect Hygiene clips in order to withstand pressure during cleaning and to minimise.
M249
M249
Download installation guide
IG104
-& 105 Hygien Inspection
(662.72 kB)
Quantity specification (excl. wastage)
Installation diagram (M249) for Ecophon Hygiene Foodtec A C3
Size, mm
600x600
1200x600
1 Ecophon Hygiene Foodtec A
2,8/m²
1,4/m²
2 Connect T24 Main runner C3, installed at 1200 mm centres
0,9m/m²
0,9m/m²
3 Connect T24 Cross tee C3, L=1200 mm, installed at 600 mm centres
1,7m/m²
1,7m/m²
4 Connect T24 Cross tee C3, L=600 mm
0,9m/m²
-
5 Connect Adjustable hanger C3, c1200 (max distance from wall 600 mm)
0,7/m²
0,7/m²
6 Connect Hanger clip
0,7/m²
0,7/m²
7 Connect Inspection hatch C3
as required
as required
8 Connect Hygiene clip 20
11/m²
9/m²
9 Connect Hygiene clip 40
11/m²
9/m²
10 Connect Channel trim C3, fixed c300 (for 20 mm thickness)
as required
as required
11 Connect Channel trim C3, fixed c300 (for 40 mm thickness)
as required
as required
Min. overall depth of system: 150 mm
-
-
Min. demounting depth 20 mm: 150 mm
-
-
Min. demounting depth 40 mm: 170 mm
-
-
Acoustics
Acoustic:
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654.
Sound Insulation:
Not applicable.
Sound Privacy:
Not applicable
product
Hygiene Foodtec A C3, 20 mm thick
Hygiene Foodtec A C3, 40 mm thick
o.d.s mm
200
200
absorption class
A
A
Technical info
Accessibility:
The tiles are demountable. Minimum demounting depth according to installation diagram. The tiles are secured using Hygiene Clip 20 to allow for effective in-situ cleaning. The clips are easily removable from above the ceiling. A tightly sealed, easy-to-open Hygiene Inspection hatch is available to simplify access to the ceiling void.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet cleaning on all surfaces and high-pressure washing twice a year. Can withstand the use of common disinfecting chemicals.
Visual appearance:
Colours: See Ecophon colour range.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate:
Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 5/M2.5.
Environmental influence:
Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. See Technical properties, Fire safety.
Country
Class
Standard
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Installation:
Installed according to system range. Cut tiles must be sealed with Connect Hygiene Advance Tape.
For Acousticians
"Acoustical evaluation of rooms requires several room acoustic descriptors. Reverberation time alone is not enough!" Erling Nilsson / Acoustics Specialist Ecophon