Search
Products
Solutions
References
Acoustics
Functional demands
Contact
About Ecophon
Career
SITEMAP
Focus
Focus additional systems
Master
Combison
Gedina
Advantage
Access
Sombra
Hygiene
Super G
Wall Panel
Ecophon Lighting
Focus™ A
Focus™ B
Focus™ C
Focus™ Dg
Focus™ Ds
Focus™ E
Focus™ Ebx
Focus™ F
Focus™ Wing
Focus Edge™ 500
Ecophon Focus™ Flexiform
Focus™ S-Line
Focus™ L-Line
Ecophon Focus™ Quadro E
Focus™ Frieze
Master™ A
Master™ B
Master™ C
Master™ Ds
Master™ E
Master™ F
Master™ Solo S
Master™ Baffle
Combison™ Uno A
Combison™ Uno Ds
Combison™ Duo A
Combison™ Duo E
Combison™ Barrier
Gedina™ A
Gedina™ E
Advantage™ A
Advantage™ E
Access™ A
Access™ C
Access™ E
Access™ Frieze
Sombra™ A
Sombra™ Ds
Hygiene Advance™ A C4
Hygiene Advance™ A C3
Hygiene Advance™ Baffle C3
Hygiene Advance™ Protection C3
Hygiene Advance™ Wall C3
Hygiene Foodtec™ A C3
Hygiene Foodtec™ Baffle C3
Hygiene Foodtec™ Wall C3
Hygiene Protec™ A C3
Hygiene Protec™ A C1
Hygiene Labotec™ Ds C1
Hygiene Performance™ A C4
Hygiene Performance™ A C3
Hygiene Performance™ A C1
Hygiene Meditec™ A C1
Hygiene Meditec™ E C1
Hygiene Lavanda™ T5 C3
Hygiene Foodtec™ Protection C3
Super G™
Super G™ Plus
Super G™ Dp XL
Wall Panel™ A
Wall Panel™ C
Ecophon Illuminated Level Change
Light Coffer
Dot™
Square 43™
Line™
WingLight™
Room types
Ideas and solutions
Colours and surfaces
Integrated lighting
Download our brochures here!
Concrete Core Activation
Connect Grids
Local references Germany
Local references Italy
Local references Sweden
Local references Netherlands
Local references
For Architects
For Acousticians
For Clients
For Users
Sound in offices
Noise in Offices
Ecophon Acoustic Bulletin
Accessibility
Limpieza
Visual appearance
Environment
Our certifications
Influence of climate
Fire Safety
Mechanical properties
CE-marking
Ecophon partners
Request information
Contact
ECO magazine- subscription
Subscribe to EcoMagazine
Disclaimer
Cookies
Trademarks
Testimonials
Available jobs
Workplace facts
Development opportunities
Environment Health Safety
HR Contact
Master
Master™ C
Tell a friend
Print
E-tools
Cad Support
Specifications
Maintenance manual
System and product description
Installation
Acoustics
Technical info
System range
Size, mm
600x600
Concealed
•
Direct
•
Glued
•
Thickness
40
M57
M111
M95
System and product description
Suitable for schools, open plan offices or other premises where strict demands are made on good acoustics and speech intelligibility. Ecophon Master C is installed in a suspended grid system or directly to the soffit, creating a ceiling with a smooth appearance. The bevelled edges create a narrow groove between each tile. The tiles are not demountable.
The systems consist of Ecophon Master C tiles and Ecophon Connect grid systems, with an approximate weight of 5,5 kg/m². The tiles are manufactured from high density glass wool. The visible surface is available with three different surface coatings to meet different sound absorption needs: alpha, beta and gamma. The back of the tile is covered with glass tissue. The edges are painted. The grid is manufactured from galvanized steel.
M57
M111
M95
M57
Quantity specification (excl. wastage)
Installation diagram (M57) for Master C, suspended installation
Size, mm
600x600
1 Master C
2,8/m²
2 Connect T24 Main runner, installed at 1200 mm centres (max distance from wall 300 mm)
0,9m/m²
3 Connect Wire clip
1,4/m²
4 Connect Z-profile, installed at 600 mm centres
1,7m/m²
5 Connect Splice Connector Z
0,4/m²
6 Connect Spline, L=150 mm
2,8/m²
7 Connect T-spline, L=600 mm
2,8/m²
8 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm)
0,7/m²
9 Connect Angle trim, fixed at 300 mm centres
as required
10 Connect Shadow-line trim, fixed at 300 mm centres
as required
11 Connect Inspection
as required
Min. overall depth of system: 155 mm
-
Min. demounting depth: Individual ceiling tiles are non-demountable
-
M111
Quantity specification (excl. wastage)
Installation diagram (M111) for Master C, direct installation
Size, mm
600x600
1 Master C
2,8/m²
2 Connect Z-profile, installed at 600 mm centres
1,7m/m²
3 Connect Direct fixing plate, (installed at 1200 mm centres)
1,4/m²
4 Connect Splice Connector Z
0,4/m²
5 Connect Spline, L=150 mm
2,8/m²
6 Connect T-spline, L=600 mm. To comply with fire class 'Tändskyddande beklädnad'
2,8/m²
7 Connect Angle trim, fixed at 300 mm centres
as required
8 Connect Shadow-line trim, fixed at 300 mm centres
as required
9 For installation of floating ceilings: Connect Channel trim, (height=27 mm)
as required
Min. overall depth of system: 55 mm
-
Min. demounting depth: Individual ceiling tiles are non-demountable
-
M95
Download installation guide
IG
-A-Cement
(34.28 kB)
Quantity specification (excl. wastage)
Installation diagram (M95) Master C, using A-cement
Size, mm
600x600
1 Ecophon Master C
2,8/m²
2 Connect A-cement, (diameter 40 mm)
1,4l/m²
3 Connect Spline, L=150 mm
2,8/m²
4 Connect Wood trim, L=3000 (For installation of floating ceilings)
as required
Min. overall depth of system: 43 mm
-
Min. demounting depth: The system is non-demountable
-
Visible edges should be painted
-
Acoustics
Acoustic:
product
Master C/alpha
Master C/beta
Master C/gamma
o.d.s mm
40
200
40
200
40
200
absorption class
A
A
C
C
E
E
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation:
Dn,c,w=31 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=33 dB according to ASTM E 1414 and evaluation according to ASTM E 413
Sound Privacy:
AC(1.5)=200 /alpha according to ASTM E 1111 and E 1110. /beta and /gamma are not suitable.
αp Practical sound absorption coefficient
Frequency Hz
— Ecophon Master C/alpha 200 mm o.d.s.
···· Ecophon Master C/beta 200 mm o.d.s.
--- Ecophon Master C/gamma 200 mm o.d.s.
o.d.s = overall depth of system
αp Practical sound absorption coefficient
Frequency Hz
— Ecophon Master C/alpha 40 mm o.d.s.
···· Ecophon Master C/beta 40 mm o.d.s.
--- Ecophon Master C/gamma 40 mm o.d.s.
o.d.s = overall depth of system
Technical info
Accessibility:
The tiles are not demountable.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance:
White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd*m-2lx-1. Gloss < 1.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate:
Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
Environmental influence:
Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003 when installed according to M57 or M111. See Technical properties, Fire safety.
Country
Class
Standard
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Installation:
Installed according to system range.
For Acousticians
"Acoustical evaluation of rooms requires several room acoustic descriptors. Reverberation time alone is not enough!" Erling Nilsson / Acoustics Specialist Ecophon
Copyright © 2002-2010 Ecophon Group. All rights reserved.
Trademarks
Cookies
Disclaimer
Tell a friend
Close
Your friends name:
*
Your friends email:
*
Your name:
*
Your e-mail:
*
Your message: